Continuous Air Quality Monitoring for Healthy Buildings

Improve your IEQ and IAQ performance to align with the top green building certifications

Book a demo
atmo® in the press
Sensors
  • PM1, PM2.5, PM10
  • CO2
  • TVOCs
  • Temperature
  • Humidity
  • Barometric pressure
  • CH2O (Formaldehyde)
  • Light levels
  • Noise levels

Options: O3, CO

Connectivity
  • USB-C, 50/60Hz, 5V @ 2A
  • Direct wiring, 24V AC/DC
  • PoE
Interfaces
  • Wi-Fi (802.11 b/g/n @ 2.4GHz)
  • Bluetooth 4.1
  • Ethernet
  • USB-A
  • RS-485
Data Management
  • Web/Mobile dashboards
  • BAS/BMS integration
  • REST API

Why choose Atmocube for your project?

Multiple connectivity options

With PoE as one of them, property owners can lower their operating expenses for both new and existing buildings

No annual replacement

Easy recalibration services with necessary documentation

Various data visualization tools and reports

Web and mobile dashboards for facility managers for easy data management

No batteries

Make your operations more sustainable

Data security

Connect to BAS/BMS via Modbus, MQTT and BACnet Gateway without third-party cloud access

REST API

Easily integrate the data from Atmocube in your custom system

Get points for WELL Air
WELL Requirements
Atmocube
A01 Air Quality (Part 1, Part 2 (Option 2), Part 5 partially, Part 3 (soon))
Contributes to the evaluation of the AQ, may substitute annual lab testing
A08 Air Quality Monitoring and Awareness (Part 1 & Part 2)
Requirements met (2 points)
T06 Thermal Comfort Monitoring (Part 1)
Requirements met (1 point)
T07 Humidity Control (Option 3)
Opportunity to meet
Get points for LEED v5 Air Quality Performance
Atmocube Measured Parameter
Possible Points For Option 1
Path 1a. Continuous Indoor
Air Monitoring
Path 1b. Meet Air Quality Thresholds via Continuous Monitoring
CO2 (Carbon Dioxide)
2
3 for minimum or 4 for enhanced IAQ limit
PM2.5 (Particulate Matter)
2
3 for minimum or 4 for enhanced IAQ limit
TVOC (ppm)*
2
2
Formaldehyde
1
2
Total possible points with Atmocube: 10 out of 10 for Option 1. Please refer to the LEED v5 O+M Rating System document for more details.
Sensor specifications

Measurement interval: 1 min

Parameter
Sensor model
Accuracy
CO2 (Carbon Dioxide)
Sensirion SCD 41
± 75 ppm @ 400 – 1000 ppm
± 40 ppm + 5% of m. v. @ 1000 ppm – 2000 ppm
PM2.5 (Particulate Matter)
Sensirion SPS 30
± 5 μg/m3 @ 0 – 75 μg/m3 verified by MCERTS
PM10
± 25 μg/m3 @ 0 to 100 μg/m3
TVOC (ppm)*
Sensirion SGP41
15% of the measured value
CH2O (Formaldehyde)
Sensirion SFA30
± 0.02 ppm or ± 20% of m. v., whichever is larger
Temperature
Sensirion STS35-DIS
± 0.1 °C
Relative Humidity
Sensirion SHTC3
± 2 % RH
Atmospheric Pressure
Infinion DPS310
± 1 hPa
Light Intensity
AMS TCS34725
± 10%
Background Noise Level
Knowles SPH0641LM4H-1
± 2 db

CO, O₃ – coming soon

*Using Sensirion conversion algorithm

My facility has been using Atmocubes for the past year and we have made great progress in the air quality in our laboratory thanks to them. First, the software logging system helped us easily identify the source of our air quality issues when there was a clear spike in the particulate matter from turning a machine on. The Atmocube system has also helped us with trying different counter measures to contain and improve the source. Without them, we wouldn’t have known what alleviation methods worked and didn’t work. I highly recommend Atmocubes!

Greg Stratton, Facilities Manager at NTS

Book a demo

Book a free demo
Ready to purchase samples?
Not available for personal use
Buy a sample
To book a free demo, use the calendar link
To purchase samples, fill out the form below
Not available for personal use